To properly set the owner of /etc/ssh/sshd_config.d, run the command:
$ sudo chown root /etc/ssh/sshd_config.d
Rationale
Service configuration files enable or disable features of their respective
services that if configured incorrectly can lead to insecure and vulnerable
configurations. Therefore, service configuration files should be owned by the
correct group to prevent unauthorized changes.
Shell script
The following script can be run on the host to remediate the issue.
#!/bin/bash
# Remediation is applicable only in certain platforms
if rpm --quiet -q kernel-core; then
newown=""
if id "0" >/dev/null 2>&1; then
newown="0"
fi
if [[ -z "$newown" ]]; then
>&2 echo "0 is not a defined user on the system"
else
find -P /etc/ssh/sshd_config.d/ -maxdepth 0 -type d ! -user 0 -exec chown --no-dereference "$newown" {} \;
fi
else
>&2 echo 'Remediation is not applicable, nothing was done'
fi
Ansible playbook
The following playbook can be run with Ansible to remediate the issue.
- name: Gather the package facts
package_facts:
manager: auto
tags:
- CCE-89747-0
- NIST-800-53-AC-17(a)
- NIST-800-53-AC-6(1)
- NIST-800-53-CM-6(a)
- configure_strategy
- directory_owner_sshd_config_d
- low_complexity
- low_disruption
- medium_severity
- no_reboot_needed
- name: Set the directory_owner_sshd_config_d_newown variable if represented by uid
ansible.builtin.set_fact:
directory_owner_sshd_config_d_newown: '0'
when: '"kernel-core" in ansible_facts.packages'
tags:
- CCE-89747-0
- NIST-800-53-AC-17(a)
- NIST-800-53-AC-6(1)
- NIST-800-53-CM-6(a)
- configure_strategy
- directory_owner_sshd_config_d
- low_complexity
- low_disruption
- medium_severity
- no_reboot_needed
- name: Ensure owner on directory /etc/ssh/sshd_config.d/
ansible.builtin.file:
path: /etc/ssh/sshd_config.d/
follow: false
state: directory
owner: '{{ directory_owner_sshd_config_d_newown }}'
when: '"kernel-core" in ansible_facts.packages'
tags:
- CCE-89747-0
- NIST-800-53-AC-17(a)
- NIST-800-53-AC-6(1)
- NIST-800-53-CM-6(a)
- configure_strategy
- directory_owner_sshd_config_d
- low_complexity
- low_disruption
- medium_severity