Oracle Cloud Infrastructure (OCI) FastConnect is a dedicated, private connection between OCI and your environment.
This integration allows you to monitor and alert on the health, capacity, and performance of your FastConnect connection by collecting metrics and tags from the [oci_fastconnect][1] namespace
Once you set up the [Oracle Cloud Infrastructure][2] integration, ensure that any namespaces mentioned above are included in your [Connector Hub][3].
oci.fastconnect.bits_received (count) | Number of bits received on the FastConnect interface at the Oracle end of the connection. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as bit |
oci.fastconnect.bits_sent (count) | Number of bits sent from the FastConnect interface at the Oracle end of the connection. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as bit |
oci.fastconnect.bytes_received (count) | Number of bytes received on the FastConnect interface at the Oracle end of the connection. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as byte |
oci.fastconnect.bytes_sent (count) | Number of bytes sent from the FastConnect interface at the Oracle end of the connection. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as byte |
oci.fastconnect.connection_state (gauge) | The values are up (1) or down (0). For a virtual circuit, the operational state of the virtual circuit's interface. For a cross-connect group, this reflects the overall operational state of the cross-connects that make up the cross-connect group (LAG). If at least one of the cross-connects is up, this value is up (1). If all the cross-connects in the group are down, this value is down (0). |
oci.fastconnect.ipv_4bgp_session_state (gauge) | The values are up (1) or down (0). The status of the IPv4 BGP session for a virtual circuit. |
oci.fastconnect.ipv_6bgp_session_state (gauge) | The values are up (1) or down (0). The status of the IPv6 BGP session for a virtual circuit. |
oci.fastconnect.packets_discarded (count) | Number of packets discarded at the Oracle end of the connection. Shown as packet |
oci.fastconnect.packets_error (count) | Number of packets dropped at the Oracle end of the connection. Dropped packets indicate a misconfiguration in some part of the overall system. Check if there's been a change to the configuration of your VCN, the virtual circuit, or your CPE. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as packet |
oci.fastconnect.packets_received (count) | Number of packets received on the FastConnect interface at the Oracle end of the connection. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as packet |
oci.fastconnect.packets_sent (count) | Number of packets sent from the FastConnect interface at the Oracle end of the connection. For a cross-connect group (LAG), the value is the sum across all cross-connects in the group. Shown as packet |
OCI FastConnect does not include any service checks.
OCI FastConnect does not include any events.
Need help? Contact [Datadog support][5]. [1]: https://docs.oracle.com/en-us/iaas/Content/Network/Reference/fastconnectmetrics.htm [2]: https://docs.datadoghq.com/integrations/oracle_cloud_infrastructure/ [3]: https://cloud.oracle.com/connector-hub/service-connectors [4]: https://github.com/DataDog/integrations-internal-core/blob/main/oci_fastconnect/metadata.csv [5]: https://docs.datadoghq.com/help/