Netnology Cisco SD-WAN

Supported OS Linux

Versión de la integración1.0.1

To find out if this integration is available in your organization, see your Datadog Integrations page or ask your organization administrator.

To initiate an exception request to enable this integration for your organization, email support@ddog-gov.com.

Información general

Este check monitoriza controladores Cisco SD-WAN a través del Datadog Agent utilizando una plataforma SD-WAN proporcionada por Netnology. El check permite a los usuarios monitorizar el estado de la red y el rendimiento de varios controladores Cisco SD-WAN simultáneamente. La información recopilada entonces puede utilizarse para la creación de dashboards agregados y notificaciones en los monitores/alertas configurados.

Actualmente, sólo los dispositivos de Cisco vManage son compatibles como destinos del controlador SD-WAN.

Configuración

La integración de Netnology Cisco SD-WAN no está incluida en el paquete del Datadog Agent, por lo que deberás instalarlo manualmente.

Instalación

Para el Agent v7.21+/v6.21+, sigue las instrucciones siguientes para instalar el check en tu host. Consulta Utilizar integraciones de la comunidad para instalar con el Docker Agent o versiones anteriores del Agent.

  1. Ejecuta el siguiente comando para instalar la integración del Agent:

    datadog-agent integration install -t nn_sdwan==1.0.1
    
  2. Configura tu integración como si fuese una integración básica

Configuración

  1. Edita el archivo nn_sdwan.d/conf.yaml en la carpeta conf.d/ en la raíz de tu directorio de configuración del Agent para comenzar a recopilar tus datos de rendimiento de Cisco SD-WAN. Consulta ejemplo de nn_sdwan.d/conf.yaml para ver todas las opciones disponibles de configuración.

  2. Reinicia el Agent.

Validación

Ejecuta el subcomando de estado del Agent y busca nn_sdwan en la sección Checks.

Datos recopilados

Métricas

nn_sdwan.app_aware_routing.jitter
(gauge)
The change in latency for packets when traversing a link
Shown as millisecond
nn_sdwan.app_aware_routing.latency
(gauge)
The time required for packets to traverse a link
Shown as millisecond
nn_sdwan.app_aware_routing.loss_percentage
(gauge)
The percentage of packets lost during transmission
Shown as percent
nn_sdwan.app_aware_routing.rx_octets
(gauge)
The number of octets received on a link
Shown as byte
nn_sdwan.app_aware_routing.tx_octets
(gauge)
The number of octets transmitted on a link
Shown as byte
nn_sdwan.cert_summary
(gauge)
The number of normal, warning, and invalid certificates
nn_sdwan.connection_summary_stats_error
(gauge)
The number of certificate errors for WAN edges, vBond devices, and vSmart devices
nn_sdwan.connection_summary_stats_total
(gauge)
The number of certificates for WAN edges, vBond devices, and vSmart devices
nn_sdwan.device_control_status
(gauge)
The number of devices that are up, partially up, and/or down
nn_sdwan.reboot_count
(gauge)
The number of times in the past 24 hours that the controller has rebooted
nn_sdwan.site_health
(gauge)
The number of sites that are up, contain warnings, and/or are down
nn_sdwan.top_app_stats
(gauge)
The number of bytes sent across a link by application
Shown as byte
nn_sdwan.transport_interface
(gauge)
The number of links with active throughput within a particular range
nn_sdwan.vmanage_count
(gauge)
The number of devices for each status
nn_sdwan.wan_edge_health
(gauge)
The number of normal, warning and error WAN edges
nn_sdwan.wan_edge_inventory
(gauge)
The number of deployed, authorized, staging, and total WAN edges

Eventos

La integración de Netnology Cisco SD-WAN no incluye ningún evento.

Checks de servicio

nn_sdwan.sdwan_controller.online

Returns CRITICAL if the remote host cannot be pinged, WARNING if the controller can be pinged but is not responding to API calls, and OK otherwise.

Statuses: ok, warning, critical

Solucionar problemas